Model DI-5B47K-14
Isolated 0-1200°C (32-2192°F) 5B-style Amplifier
Stock
- Interfaces to Type K Thermocouples
- 0°C to +1200°C (+32°F to +2192°F) measurement range
- Linearizes Thermocouple Signal
- High Level Voltage Outputs
- 1500Vrms Transformer Isolation
- ANSI/IEEE C37.90.1-1989 Transient Protection
- Input Protected to 240VAC Continuous
- 160dB CMR
- 95dB NMR at 60Hz, 90dB at 50Hz
- ±1µV/°C Drift
- CSA Certified
- View Dimensions and pinout
Description
Each DI-5B47 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized and converted to a high level analog voltage output (see block diagram). This voltage output is logic switch controlled, which allows these modules to share a common analog bus without the requirement of external multiplexers.
The DI-5B modules are designed with a completely isolated computer side circuit which can be floated to ±50V from Power Common, pin 16. This complete isolation means that no connection is required between I/O Common and Power Common for proper operation of the output switch. If desired, the output switch can be turned on continuously by simply connecting pin 22, the Read-Enable pin to I/O Common, pin 19. The DI-5B47 can interface to eight industry standard thermocouple types: J, K, T, E, R, S, N, and B. Its corresponding output signal operates over a 0 to +5V range. Each module is cold-junction compensated to correct for parasitic thermocouples formed by the thermocouple wire and screw terminals on the mounting hardware. Upscale open thermocouple detect is provided by an internal pull-up resistor. Downscale indication can be implemented by installing an external 47MΩ resistor, ±20% tolerance, between screw terminals 1 and 3.
Signal filtering is accomplished with a six-pole filter which provides 95dB of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter are on the field side of the isolation barrier, and the other four are on the computer side.
After the initial field-side filtering, the input signal is chopped by a proprietary chopper circuit. Isolation is provided by transformer coupling, again using a proprietary technique to suppress transmission of common mode spikes or surges. The module is powered from +5VDC, ±5%.
A special circuit in the input stage of the module provides protection against accidental connection of power-line voltages up to 240VAC.
Accessories
Description
16-channel backplane for 5B modules. Each module has its own analog bus. For use with DI-5B Modules.
Description
Single-channel backplane. For use with DI-5B Modules.
Description
Dual-channel backplane. For use with DI-5B Modules.
Description
8-position analog I/O backplane, non-multiplexed. For use with DI-5B Modules.
Description
Base element with snap foot required for use with models DI-5B03 and DI-5B04 Backplanes. For use with DI-5B Modules.
Description
5V DC Power Supply for use with both DI-5B and DI-8B Backplanes.
Description
Side element required for use with models DI-5B03 and DI-5B04 Backplanes. For use with DI-5B Modules and Backplanes.
Specifications
Input Range: | 0ºC to +1200ºC (+32ºF to +2192ºF) -0.1V to +0.5V |
Thermocouple Type: | K |
Accuracy: | ±0.96ºC (Includes conformity, hysteresis, and repeatability. Does not include CJC accuracy.) |
Input Bias Current: | -25nA |
Input Resistance: | Normal: 50MΩ Power Off: 40kΩ Overload: 40kΩ |
Input Protection: | Continuous: 240Vrms max Transient: ANSI/IEEE C37.90.1-1989 |
CMV, Input to Output: | Continuous: 1500Vrms max Transient: ANSI/IEEE C37.90.1-1989 |
CMR (50Hz or 60Hz): | 160dB |
NMR: | 95dB at 60Hz, 90dB at 50Hz |
Stability: | Input Offset: ±1µV/°C* Output Offset: ±20µV/°C Gain: ±25ppm/°C |
Noise: | Input, 0.1 to 10Hz: 0.2µVrms Output, 100kHz: 300µVp-p, 150µVrms |
Bandwidth, -3dB: | 4Hz |
Response Time, 90% Span: | 0.2s |
Output Range: | 0V to +5V |
Output Resistance: | 50Ω |
Output Protection: | Continuous Short to Ground |
Output Selection Time (to ±1mV of VOUT) |
6µs at Cload = 0 to 2000pF |
Output Current Limit: | ±14mA max |
Output Enable Control: | Max Logic “0”: +0.8V Min Logic “1”: +2.4V Max Logic “1”: +36V Input Current, “0”, “1”: 0.5µA |
Open Input Response: | Upscale |
Open Input Detection Time: | 10s |
Cold Junction Compensation: | Accuracy, 25°C: ±0.25°C Accuracy, +5°C to +45°C: ±0.5°C Accuracy, -40°C to +85°C: ±1.25°C |
Power Supply Voltage: | +5VDC ±5% |
Power Supply Current: | 30mA |
Power Supply Sensitivity: | ±2µV/% RTI (RTI-Referenced to Input) |
Environmental: | Operating Temperature: -40ºC to +85ºC Storage Temperature: -40ºC to +85ºC Relative Humidity: 0 to 95% Noncondensing RFI Susceptibility: ±0.5% Span Error at 400MHz, 5W, 3ft |
Mechanical Dimensions: | 2.28" × 2.26" × 0.60" (58mm × 57mm × 15mm) |
*This is equivalent to °C as follows: Type J = 0.020°C/°C, Types K & T = 0.025°C/°C, Type E = 0.016°C/°C, Types R & S = 0.168°C/°C, Type N = 0.037°C/°C, Type C = 0.072°C/°C.
Articles
Bandwidth Considerations for DI-5B and DI-8B Signal Conditioning Modules
Learn the Importance of Isolation In Four Easy Lessons
How To Calibrate Strain Gage-Based Transducers Using DI-5B38 Strain Amplifiers